Sales & Information Tel: 0121 746 3500

Swegon Gold RXHC Range

A solution with energy and simplicity in mind.

Any occupied space requires the correct quantity of outside air to displace any stale air and create a fresh environment.

By utilizing heat pump technology and heat recovery, Swegon’s fresh air systems provides a cost-effective and energy efficient way of installing a 100% fresh air system with a balanced extract.

Packaged Heat Pump AHU

Features & Benefits

This Packaged heat pump air handling unit offers full flexibility in control and design to provide conditioned fresh air direct to the room or air-conditioning system, whether that be fan coils, chilled beams, VRF or VAV. The unit consists of high spec components offering the very best in energy efficiency; all is required is a power supply and ductwork offering the following advantages and benefits.

Key Features

• Energy efficient.

• Compact footprint.

• Modular constructions.

• Inverter compressors.

• EC fans.

• High efficiency speed regulating sorption thermal wheel.

• Advanced controls with remote key pad.

• Extensive range.

• Integral heating and cooling.

• Plug and play configuration.

• Patent defrost system.

Packaged Heat Pump AHU

Description of Operation

A common problem with the control of fresh air is the variance in the external temperature and problems associated with the use of direct expansion as the cooling/heating medium. With the advanced control function of the Gold RX/HC units, inverter compressors, regulation of the thermal wheel and patented defrost system, Swegon have developed the perfect packaged solution.

Summer / Cooling Mode

Fresh air enters the unit passing through the thermal wheel, which transfers cooling energy from the room return air, the air then passes across the supply air coil where the low temperature refrigerant reduces the supply air temperature to an adjustable value. At the same time the room air passes first through the thermal wheel to maximise heat recovery, and then the heat exchanger, discharging the unwanted heat to atmosphere.

Winter / Heating Mode

Fresh air enters the unit passing through the thermal wheel, which transfers heating energy from the room return air, the air then passes across the supply air coil where the high temperature refrigerant increases the supply air temperature to an adjustable value. At the same time the room air passes first through the thermal wheel to maximise heat recover, and then the heat exchanger, discharging the unwanted cold air to atmosphere.

Free Cooling Mode

When there is a cooling demand from the room, but the external air temperature is lower than the room temperature, then cooling is activated without the use of the refrigerant cycle and the speed of the thermal wheel is regulated to maintain the supply air temperature.

Packaged Heat Pump AHU

Technical Information

Features & Benefits

Technical Overview

Download our Specifiers Guide

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Nullam id dolor id nibh ultricies vehicula ut id elit. Curabitur blandit tempus porttitor. Cum sociis natoque penatibus et magnis dis parturient montes, nascetur.

For Assistance or Sales Tel: 0121 746 3500

The COR & COR Synergy Technical Support

Fusce dapibus, tellus ac cursus commodo, tortor mauris condimentum nibh, ut fermentum massa justo sit amet risus. Cras justo odio, dapibus ac facilisis in, egestas eget quam.

Discover how EasyAir conditioning can provide solutions for you today.

0